Utini Two Way Output Current Voltage Signal Generator 4-20mA/0-10V Signal Source Transmitter

Price: $112.89
Product prices and availability are accurate as of 2020-12-13 19:47:08 UTC and are subject to change. Any price and availability information displayed on https://www.amazon.com/ at the time of purchase will apply to the purchase of this product.
CERTAIN CONTENT THAT APPEARS ON THIS SITE COMES FROM AMAZON SERVICES LLC. THIS CONTENT IS PROVIDED 'AS IS' AND IS SUBJECT TO CHANGE OR REMOVAL AT ANY TIME.

Manufacturer Description

HV300 0-10V 0-20MA current signal generator
1. Summary:
HV300 is a small current and voltage signal generator, which can also produce 0 - 20MA current signals and 0 to 10V voltage signals, respectively.
The module is simple to use, and the input data is input by key operation, and the output signal is updated immediately.
Two. Product Applications:
Signal generator.
Instrument calibration.
Three. Technical parameter table:
Serial number project parameter Company Remarks
1 Current signal range 0 ~ 20 MA
2 Range of voltage signal 0 ~ 10 V
3 working voltage 7~12 VDC
4 Working current <50 MA
5 working temperature -40 C ~ 65 C Centigrade
6 Storage temperature -40 C ~ 65 C Centigrade
7 size 57*45*20 Mm Long X wide X high
Four, interface description and related operations
P4 interface (power supply)
VDD: power source (7 ~ 12V)
GND: power supply negative pole
P2 interface (output signal)
QI: current signal output.
GND: power supply negative.
QV: voltage signal output.
GND: power supply negative.
Four, key description
UP: is added to the key.
DOWN: is self - reducing.
ENTER: selects the operating bits of the data set / (open / close by the set change signal).
FUN: voltage setting / current setting.
4.1. Control current output
Interface display font:
The first line "1.QI= 0->20mA ON"
The second line "*0.001 10.000mA"
Key operation:
ENTER: selects the operating bits of the data set / (open / close by the set change signal).
4.2. Control voltage output
Interface display font:
The first line "2.QV= 0->10V ON"
The second line "*0.001 5.000V"
Key operation:
ENTER: selects the operating bits of the data set / (open / close by the set change signal).
4.3. Save the setting parameters
Interface display font:
The first line "3. Save SET"
The second line ""
Key operation:
ENTER:

Product Features

Signal generator. Instrument calibration. Three. Technical parameter table: Serial number project parameter Company Remarks 1 Current signal range 0 ~ 20 MA