Utini DDS New Square Wave Pulse Signal Generator Signal Source Frequency Range 1KHz~68MHz

Price: $112.89
Product prices and availability are accurate as of 2020-12-13 16:27:15 UTC and are subject to change. Any price and availability information displayed on https://www.amazon.com/ at the time of purchase will apply to the purchase of this product.
CERTAIN CONTENT THAT APPEARS ON THIS SITE COMES FROM AMAZON SERVICES LLC. THIS CONTENT IS PROVIDED 'AS IS' AND IS SUBJECT TO CHANGE OR REMOVAL AT ANY TIME.

Manufacturer Description

1. Summary:
HM345 is a small signal generator has two outputs, one can produce 10KHz frequency, duty cycle adjustable pulse signal. the other way can produce 1KHz to 68MHz pulse signal.
The module is simple to use, and the input frequency data is input by key operation, and the output frequency is updated immediately.
Two. Product Applications:
Signal generator.
Instrument calibration.
Direct current motor control.
Three. Technical parameter table:
Serial number project parameter unit notes
1 pulse 1 signal range 1~10000 Hz pulse signal
2 pulse 1 duty ratio range 0 ~ 100% space ratio
3 pulse 1 signal amplitude 5 VDC maximum amplitude 5.0Vp
4 pulse 2 signal range 1~68000 kHz pulse signal
5 pulse 2 duty ratio range 50% occupied space ratio
6 pulse 2 signal amplitude 5 VDC maximum amplitude 5.0Vp
7 pulse 2 signal precision <1%%
8 working voltage 7~12 VDC
9 working current <50 mA
10 size 57*45*20 mm long X wide X height
Four, interface description and related operations
P1 interface (power supply)
VDD: power source (7 ~ 12V)
GND: power supply negative pole
P2 interface
PWM: first pulse signal output ().
POUT: second pulse signal output ().
GND: power supply negative.
Five, key description
FUN: (select the location of the data set) or (long by saving the set parameter function).
UP: on the page.
DOWN: next page.
ADD: is added to the key.
SUB: is self - reducing.
Six. Interface display and Operation Descriptions:
6.1. Set the frequency of the pulse signal
Interface display font:
The first line "1. PWM = 10K"
The second line "*1 1000Hz"
Key operation:
FUN: function key. (select the operating position of setting the data) or (according to the function of saving and setting parameters)
ADD: self - added key.
SUB: self reducing key.
6.2. Setting up the duty ratio of pulse sign

Product Features

Signal generator. Instrument calibration. Direct current motor control. Three. Technical parameter table: Serial number project parameter unit notes