Function:
-. Select sensitivity or vertical position. The selected parameter indicator will be highlighted.
-. Select timebase or horizontal position. The selected parameter indicator will be highlighted.
-. Select trigger mode, trigger level. Ad trigger edge. The selected parameter indicator will be highlighted.
-. Enter HOLD state (freeze waveform). Press it again will de-freeze.
-. Adjust the parameter selected (highlighted). Short press toggles Fast Adjustment mode.
-. Set couple to DC, AC, or GND. When GND is selected the scope input is isolated from inpur signal and connected to ground (0V input).
Specification:
Max Realtime Sample rate: 1MSa/s
Analog Bandwidth: 0--200KHz
Sensitivity Range: 5mV/div - 20V/div
Max Input Voltage: 50Vpk (1X probe)
Input Impedance: 1M ohm/20pF
Resolution: 12bit
Record Length: 1024 points
Time Base Range: 500s/Div - 10us/Div
Trigger Modes: Auto, Normal, and Single
Trigger Position: Center of buffer
Power Supply: 9VDC (0 - 10V)
Current Consumption: ~120mA@9V
Dimension: 105 x 75 x 22mm
Weight: 100g (without probe and PS)
Package includes:
1 x DSO Shell Oscilloscope
1 x BNC-clip Cable
1 x Adaptor
1 x User Manual
Update Oscilloscope Kit: It reaches 5mV/div -- 20V/div. Also, this updated version can be handheld.
Integrated: Display and MCU are mounted on the same board (mainboard) to avoid using inter-board pin-headers.
Measurements including Vmas, Vmin, Vavr, Vpp, Vrms. Freq., Cycle, Pulse width, and Duty cycle.
Save & Recalled: The currently displayed waveform is saved to EEPROM. The existing data in EEPROM will be over-written. Recalled waveform is always displayed in Hold state.
Easy to use: It has been added the rotary encoder, makes parameter adjustment more quicker and easier